Library

Coplasma Price List

PRICE LIST AND RETURN OF INVESTMENT full details in CoPlasma Savings

Flow Rate m3/h250050007500100001250015000175002000022500250002750030000
Investment
Cells per ranks used (Model Ref.)11.52.5345567899
FE 600112344466899
FE 300011002202000
Energy consumption (2 ranks) of CoPlasma system kW0.0480.0660.0980.1120.160.2050.2050.2240.2690.3040.3360.336
System Average Selling Price (2 ranks without frames & accessories)€2,613€3,943€6,023€6,773€9,386€12,536€12,536€13,546€16,696€18,239 €20,319€20,319
Return of Investment
Energy Saving Analysis
Power input for fan equipped with clean mechanical filters (210+250Pa)1.242.483.724.976.217.458.699.9311.1712.4113.6514.90
Power input for fan equipped with CoPlasma system CoPlasma (124Pa)0.801.592.393.183.984.785.576.377.167.968.759.55
Filtration Efficiency 1 Rank (for information only)97.58%97.58%95.42%96.13%95.69%95.42%95.84%96.13%95.40%95.69%95.15%95.02%
Filtration Efficiency 2 Ranks99.94%99.94%99.75%99.82%99.77%99.75%99.79%99.82%99.75%99.77%99.72%99.71%
Energy saving kW (using Electrostatic Filtration with 2 ranks)0.400.821.241.672.072.472.913.343.744.154.565.01
Saving on 18hours/day/year kWh261154208136109711358216213191402194224573272692998632912
Energy Saving 0.23€/kWh (European average electricity cost) €600.601,246.531,871.302,523.273,123.873,729.004,402.135,046.555,651.686,271.926,896.697,569.82
Maintenance Costs Saving Analysis
CoPlasma system with 2 ranks
Wires per rank (17 – 8) 3.4€17254251688484102118136153153
Springs per ranks 1.3€345084102136168168204236272306306
Replacing Costs 2.5% components/year €5.17.512.615.320.425.225.230.635.440.845.945.9
Washing (5.5€ for each cells by client) every 6 months2244666688132132132176176198198
Maintenance Total Amount for 2 ranks FE cells27.1051.5078.6081.30108.40157.20157.20162.60211.40216.80243.90243.90
System with mechanical filtration
Filter F.. Replacement 4 times per year (82€ 600×600 & 41€ 600×300)328.00492.00820.00984.001,312.001,640.001,640.001,968.00 2,296.002,624.00 2,952.002,952.00
Filter replacement H.. 4 times per year (198€ 600×600 & 125€ 600×300)792.001,292.002,084.002,376.003,168.004,168.004,168.004,752.005,752.006,336.007,128.007,128.00
Mechanical Filtration Maintenance Total Amount €1,120.001,784.002,904.003,360.004,480.005,808.005,808.006,720.008,048.008,960.0010,080.0010,080.00
Saving on maintenance €1,092.901,732.502,825.403,278.704,371.605,650.805,650.806,557.407,836.608,743.209,836.109,836.10
Total Savings €1,693.502,979.034,696.705,801.977,495.479,379.8010,052.9311,603.9513,488.2815,015.1216,732.7917,405.92

Note: The Energy saving is considered on an overall pressure loss on the air handling unit and air distribution system 1100Pa and not only on the pressure difference of the filters